| EXRS 2006 Paris, France "Silicon Drift Detectors Refined on Energy Resolution, Count Rate Performance and Radiation Entrance Window" |
Dr. Heike Soltau |
| IWoRID 2006 Pisa, Italy Imaging and Spectroscopy with Modern Silicon Radiation Detectors |
Dr. Heike Soltau |
| M&M 2006, Chicago, USA "Optimization of the Peak-to-Background Ratio and the Low Energy Response of Silicon Drift Detectors for High Resolution X-Ray Spectroscopy" |
Dr. Heike Soltau |
| Denver X-Ray Conference 2006 "Optimization of the Peak-to-Background Ratio and the Low Energy Response of Silicon Drift Detectors for High Resolution X-ray Spectroscopy" |
Dr. A. Niculae |
| IMC 2006 Japan "Silicon Drift Detectors Optimized for SEM-EDS" |
Dr. Heike Soltau |
| Optimized readout methods of silicon drift detectors for high-resolution X-ray spectroscopy NIM A 568, 2006, pp. 336-342 |
A. Niculae, P. Lechner, H. Soltau, G. Lutz, L. Strüder, C. Fiorini, A. Longoni |
| Monolithic arrays of silicon drift detectors for medical imaging applications and related CMOS readout electronics NIM A 560, 2006, pp. 148 – 152 |
C. Fiorini, A. Longoni, M. Porro, F. Perotti, P. Lechner, L.Strüder |
| Time Resolved X-ray Spectroscopic Imaging with novel Silicon Drift Detectors IEEE TNS 2006, Vol. 53 No. 1, pp. 373-377 |
A. Castoldi, A. Galimberti, C. Guazzoni, L. Strüder |
| A large area monolithic array of silicon drift detectors for medical imaging NIM A 568, 2006, 1, pp. 096-101 |
Fiorini, C., A. Gola, A. Longoni, M. Zanchi, A. Restelli, F. Perotti, P. Lechner, H. Soltau, L. Strüder |
| Gamma-ray spectroscopy with LaBr2: Ce scintillator readout by silicon drift detectors IEEE TNS, 2006, Vol. 53, 4, 2, pp. 2392-2397 |
Fiorini, C., A. Gola, M. Zanchi, A. Longoni, P. Lechner, H. Soltau, L. Strüder |
| Spectroscopic Performance of the DEPMOS Detector-Amplifier Device With Respect to Different Filtering Techniques and Operating Conditions IEEE TNS, 2006, Vol. 53, 1, pp. 401-408 |
Porro, M., G. Ferrari, P. Fischer, O. Hälker, M. Hartner, S. Herrmann, N. Hörnel, R. Kohrs, H. Krüger, P. Lechner, G. Lutz, I. Peric, R. Richter, L. Strüder, J. Treis, M. Trimpl, N. Wermes |
| Study of noise and spectroscopic performance of DEPMOSFET matrix prototypes for XEUS NIM A 568, 2006, 1, 191-198 |
Treis, J., P. Fischer, O. Hälker, M. Marter, S. Herrmann, R. Kohrs, H. Krüger, P. Lechner, G. Lutz, I. Peric, R.H. Richter, L. Strüder |
| Sub-electron noise measurements on repetitive non-destructive readout devices. NIM A 566, 2006, 2, pp. 536-539 |
Wölfel, S., S. Herrmann, P. Lechner, G. Lutz, M. Porro, R.H. Richter, L. Strüder, J. Treis |
| Development of macropixel detectors. NIM A 568, 2006, pp. 207-216 |
Zhang, C., P. Lechner, G. Lutz, M. Porro, R. Richter, J. Treis, L. Strüder, S. Nan Zhang |
| The MOS-type DEPFET pixel sensor for the ILC environment. NIM A 565, 2006, 1, pp. 165-171 |
Andricek, L., P. Fischer, K. Heinzinger, S. Herrmann, D. Herz, M. Karagounis, R. Kohrs, H. Krüger, P. Lechner, G. Lutz, H.G. Moser, I. Peric, L. Reuen, R.H. Richter, C. Sandow, M. Schnecke, F. Schopper, L. Strüder, E.V. Törne, J. Treis, M. Trimpl, J. Velthuis, N. Wermes, S. Wölfel |
| The focal plane of the Simbol-X space mission. Proceedings of SPIE, 2006, Vol. 6276, 627617 |
Dirks, B.P.F., P. Ferrando, U. Briel, O. Gevin, E. Kendziorra, P. Laurent, O. Limousin, F. Lugiez, J. Martignac, M. Authier, C. Chapron, P. Lechner, G. Pareschi, Y. Rio, J.P. Roques, P. Salin, L. Strüder |
| Fast timing with XEUS: evaluation of different detector concepts. Proceedings of SPIE, 2006, Vol. 6266, pp. 62661Y-1-62661Y-8 |
Kendziorra, E., M. Martin, A. Santangelo, J. Wilms, D. Barret, G. Skinner, L. Strüder, P. Lechner, J. Treis |
| XRF spectrometers based on monolithic arrays of silicon drift detectors: elemental mapping analyses
and advanced detector structures. IEEE TNS 2006, Vol. B7053, pp. 641-647 |
Longoni, A., C. Fiorini, C. Guazzoni, S. Buzzetti, M. Bellini, L. Strüder, P. Lechner, A. Bjeoumikhov, J. Kernmer |
| Test setup for DEPMOSFET matrices for XEUS. Proceedings of SPIE, 2006, Vol. 6266, pp. 62663P-1-62663P-8 |
Martin, M., E. Kendziorra, T. Schanz, A. Santangelo, J. Wilms, J. Treis, S. Herrmann, L. Strüder, P. Lechner, P. Fischer, I. Peric, D. Barret |
| Advancements in DEPMOSFET device developments for XEUS. Proceedings of SPIE, 2006, Vol. 6276, 62760Z |
Treis, J., L. Bombelli, R. Eckart, C. Fiorini, P. Fischer, O. Hälker, S. Herrmann, P. Lechner, G. Lutz, I. Peric, M. Porro, R.H. Richter, G. Schaller, F. Schopper, H. Soltau, L. Strüder, S. Wölfel |
| Silicon drift photodetectors for scintillation readout in medical imaging. NIM A 571, 2006, pp. 126-129 |
Fiorini, C., A. Gola, M. Zanchi, A. Longoni, H. Soltau, L. Strüder |
| A high speed pnCCD detector system for optical applications. NIM A 568, 2006, 1, pp. 118-123 |
Hartmann, R., W. Buttler, H. Gorke, S. Herrmann, P. Holl, N. Meidinger, H. Soltau, L. Strüder |
| A PNCCD detector system for high speed optical applications. Scientific detectors for astronomy 2005: Explorers of the Photon Odyssey, (Eds.) Beletic, J.E.; Beletic, J.W.; Amico, P. Astrophysics and Space Science Library. Springer, Dordrecht, The Netherlands, 293-302 (2006). |
Hartmann, R., H. Gorke, N. Meidinger, H. Soltau, L. Strüder |
| Systemaatic testing and results of X-ray CCDs developed for eROSITA and other applications. Proceedings of SPIE, 2006, Vol. 6276, pp. 627618-1-627618-11 |
Meidinger, N., R. Andritschke, O. Hälker, R. Hartmann, G. Hartner, G. Hasinger, S. Herrmann, P. Holl, E. Hyde, N. Kimmel, E. Pfeffermann, P. Predehl, H. Soltau, L. Strüder |
| Multilinear silicon drift detectors for X-ray and Compton Imaging. NIM A 568, 2006, 1, pp. 89-94 |
Castoldi, A., A. Galimberti, C. Guazzoni, P. Rehak, R. Hartmann, L. Strüder |
| The direct measurement of the signal charge behaviour in pnCCDs with subpixel resolution. NIM A 568, 2006, 1, pp. 128-134 |
Kimmel, N., J.S. Hiraga, R. Hartmann, N. Meidinger, L. Strüder |
| Reconstruction method for the charge collection function of pnCCDs using data obtained with the mesh experiment. NIM A 568, 2006, 1, pp. 134-139 |
Kimmel, N., R. Hartmann, P. Holl, N. Meidinger, L. Strüder |
| Next generation of pnCCDs for X-ray spectroscopy and imaging. NIM A 568, 2006, 1, pp. 141-149 |
Meidinger, N., R. Andritschke, O. Hälker, R. Hartmann, S. Herrmann, P. Holl, G. Lutz, N. Kimmel, G. Schaller, F. Schopper, R.H. Richter, L. Strüder |
| pnCCD for photon detection from the near-infrared to X-rays. NIM A 565, 2006, 1, pp. 251-257. |
Meidinger, N., R. Andritschke, R. Hartmann, S. Herrmann, P. Holl, G. Lutz, L. Strüder |
| Timing properties of an Avalanche diode for single photon counting. NIM A 567, 2006, 1, pp. 272-275 |
Merck, C., P. Holl, M. Laatiaoui, G. Lutz, H.G. Moser, N. Otte, R.H. Richter, L. Strüder |
| High Resolution Imaging X-Ray CCD Spectrometers, Handbook of Practical X-ray Fluorescence Analysis. (Eds.) B. Beckhoff, B. Kanngieser, N. Langhoff, R. Wedell, H. Wolff. Springer, 262-284 (2006). |
Strüder, L., N. Meidinger, R. Hartmann |
| Analysis of the charge collection process in pnCCDs. Proceedings of SPIE, 2006, Vol. 6276, pp. 62760D-1-62760D-11 |
Kimmel, N., R. Hartmann, P. Holl, N. Meidinger, R. Richter, L. Strüder |